KEW 8129|FLEXIBLE CLAMP SENSOR|PRODUCTS|KYORITSU

Font Size
Small
Medium
Large

FLEXIBLE CLAMP SENSOR

KEW 8129

KEW 8129
CE
Ø150mm
■KEW8129-01 (for 1ch)
■KEW8129-02 (for 2ch)
■KEW8129-03 (for 3ch)
• Flexible for various test fields
• Can measure AC current up to 3000A
• Flexible and light weight by the air core coil used at the sensor part
• Measurable conductor size: max Φ150mm
• Designed to meet the international safety standard IEC 61010-1 CAT III 600V
  • φ150
  • MAX3000A
Applicable model *5010 *5020 6305 6315

* When you use the sensors with KEW5010/5020, please check the "Applicable model list" to check if your KEW5010/5020 can be used with the sensors.

Conductor size max.Ø150mm
Rated current 300/1000/3000A
Output voltage 300A Range : AC500mV/AC300A (1.67mV/A)
1000A Range : AC500mV/AC1000A (0.5mV/A)
3000A Range : AC500mV/AC3000A (0.167mV/A)
Accuracy ±1.0%rdg (45 - 65Hz)
Phase shift within ±1°
Cable length Sensor part : approx. 2m
Output cable : approx. 1m
Output connector MINI DIN 6PIN
Output impedance 100Ω or less
Applicable standards IEC 61010-1, IEC 61010-2-032 CAT III 600V Pollution degree2,
IEC 61326
Operating temperature and humidity range 0 - 50ºC, relative humidity 85% or less (no condensation)
Dimension 111(L) x 61(W) x 43(D) mm (except for protrusions)
Weight 8129-01 (for 1ch) Approx. 410g
8129-02 (for 2ch) Approx. 680g
8129-03 (for 3ch) Approx. 950g
Accessories 8129-01 (for 1ch) Instruction Manual, 7199 (Output Cable) x1, 9137 (Carrying Case)
8129-02 (for 2ch) Instruction Manual, 7199 (Output Cable) x2, 9137 (Carrying Case)
8129-03 (for 3ch)Instruction Manual, 7199 (Output Cable) x3, 9137 (Carrying Case)

Accessories/Optional Accessories /Related Products

  • Instruction Manual
  • Applicable model list

Instruction Manual

  • Inquiry by e-mail