LEAK LOGGER
Discontinued products
THE LEAKAGE CURRENT IS RECORDED BY 3CH INPUT
60,000 DATA IS RECORDED
60,000 data is recorded when 1ch is used and when three all channels are used, 20,000 data is recorded for each channel
Continuous measurement time
About 25 days
Data where it doesn’t disappear even if battery is consumed
Data doesn’t disappear by using the nonvolatile memory when the battery is consumed and the battery is exchanged. (warranty for 10 years)
Product Overview
Battery residual display
The battery state is displayed by 4 stages. (When blinking is displayed, it is possible to measure for about one day)
The present time, recording intervals, the start of recording, the recording method, the name of monitoring site and the comment can be set by using supplied software
Selection of one time mode and endless mode
• One time on Stop recording when the memory is filled.
• One time off (endless) Overwrite from old data and leave the latest data.
Recall function
• The latest 10 data can be checked.
• The recall data is
Display month and date
Display hour and minute
Display current value
Specification
Measurements and precision(AC 50/60Hz)
Continuous recording mode
Range | Measurement | Accuracy | Accuracy of sensor combination |
---|---|---|---|
100mA | 0 to 100.0mA | ±1.0%rdg±5dgt | ±2.0%rdg±10dgt |
1000mA | 0 to 1000mA | ±2.0%rdg±6dgt |
Event recording mode / The maximum value recording mode
Range | Measurement | Accuracy | Accuracy of sensor combination |
---|---|---|---|
100mA | 0 to 100.0mA | ±1.5%rdg±7dgt | ±2.5%rdg±12dgt |
1000mA | 0 to 1000mA | ±2.5%rdg±8dgt |
Capture recording mode
*Accuracy of electric current adjudication is different. For details, refer to the operation manual
Range | Measurement | Accuracy | Accuracy of sensor combination |
---|---|---|---|
100mA | 0 to 100.0mA | ±3.0%rdg±2%fs | ±4.0%rdg±2.5%fs |
1000mA | 0 to 1000mA | ±4.0%rdg±2%fs |
Operation system | Successive approximation |
---|---|
Input | AC Voltage (AC 100mV/A) |
Maximum Circuit Voltage | AC 170mVrms, 250mV Peak value |
Number of input channel | 3 channels |
Measurement method | True RMS |
Measurement interval | 1,2,5,10,15,20,30 sec. / 1,2,5,10,15,20,30,60 min. |
Over Range Indication | "OL"mark appears when exceeding measuring range |
Warning of voltage of battery | Battery mark display of 4 stages |
Battery life | about 25 days on the event record mode ( normal temp. ) |
Insulation resistance | 50MΩ or more |
Dimensions | 111 (L) × 60 (W) × 36 (D) mm |
Weight | approx. 255g (include batteries) |
The maximum display | 1049 counts |
Applicable standards | IEC 61010-1:2001 CAT III 300V Pollution degree 2 IEC 61326 (EMC Standard) |
Power Source | Alkaline battery LR6 × 4 |
Accessories | Instruction Manual Alkaline battery LR6 Softwear for making graphs (CD) 7148 (USB cable) 9118 (Soft Case) |
Optional | 7185 (Extension Cable) 8141 / 8142 / 8143 (Leakage current clamp sensor) 9119 (Hard carry case) 9135 (Carrying bag) |
Set Model
Model | 5000-01 | 5000-02 |
---|---|---|
Leak logger (Standard type) | 5000×1 | 5000×1 |
Leakage clamp sensor | 8141(Ø24mm)×1 | |
8142(Ø40mm)×1 | 8142(Ø40mm)×2 | |
8143(Ø68mm)×1 | 8143(Ø68mm)×1 |
Catalog & Document
-
- Product Catalog
-
- Instruction Manual
-
- Quick Manual