INFRARED THERMOMETER

KEW 5515

KEW 5515
CE
Safety with non-contact temperature measurements
• Single laser allows more accurate measurements
• Backlight display helps to read in a dark place
• Dual display: Main display shows the measured values and Sub display shows either of max, min, average or thermocouple value
• Alarm function: The upper and lower temperature limits can be set
• The red blinking Backlight indicates that the measured value is below or over the pre-set limits

* This tester can measure human skin (surface) temperature
    but isn’t suitable for body temperature measurement.

DANGER

The connector for thermocouple is not insulated. Do not make measurement using a thermocouple when there is a risk of electrical shock hazard.

WARNING
• Do not look directly into the laser.
• Do not point the laser directly at persons or animals.
• When measuring a reflective object such as mirrors, take extra caution so as not to look diffuse
   reflections.
• Keep out of reach of child or person who doesn’t have the Product handling knowledge.
• Use the Product only as specified. Do not disassemble or modify the Product.

Display features 

Relation of distance and measuring diameter

Display / Buttons

Infrared Thermometer
Measuring range -32 - 535ºC
Accuracy ±3.0ºC (-32 - -20 ºC), ±2.0ºC (-20 - +100ºC), ±2%rdg (100 - 535ºC)
Measuring element Thermopile
Infrared spectral band 5 - 14μm
Measuring diameter 1000mm/ ø78mm (Distance/ Measuring dia.: 12:1)
Repeatability Within ±1ºC
Emissivity Variable between 0.10 and 1.00 (by 0.01 steps), Before shipment: 0.95
Collimation Laser beam (Class 2, 630 - 670nm, 1mW or less) specifies the center.
Thermocouple
Thermocouple K-type*
Measuring range of 
thermocouple
-199 - 1372ºC
Accuracy of 
thermocouple
±1.5%rdg+1ºC (-40 - 1372ºC)
Response 500ms
Resolution 0.1ºC
Auto power off If no key is pressed for 6 seconds, the power is shut off automatically.
LCD display LCD with backlight (blinks in red when alarm function is activated)
Dual display Simultaneous display
(Measured value and either of max, min, average or thermocouple value.)
Operating temperature & humidity 0 - 50ºC/ 10 - 90% RH
Applicable standards IEC 61326, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-8, IEC60825-1
Battery 6F22(9V) × 1
Dimension 180 (L)×130 (W)×40 (D) mm
Weight Approx. 195g (excluding battery)
Accessories 9152(Carrying case), 6F22(9V) × 1, Instruction manual

* Commercial K-type thermocouple can be used with the product.