AC CLAMP METER

KEW 2117R

Fully Safety jaw

  • Fully Safety jaw
  • Ergonomic over-molded body gives convenient one-hand operation
  • Large easy-to-read display with 0.01A resolution
  • Accurate reading with True RMS 60/600/1000A auto-ranging
  • Long battery life
  • Safety Standard IEC 61010-1 CAT Ⅳ 300V / CAT Ⅲ 600V

3D View

Video

Specification

AC A 60.00/600.0/1000A (Auto-ranging)
±1.5%rdg±4dgt [45 - 65Hz]
±2.0%rdg±5dgt [40Hz - 1kHz]
AC V 60.00/600.0V (Auto-ranging)
±1.0%rdg±2dgt [45 - 65Hz] (600V)
±1.5%rdg±4dgt [40Hz - 1kHz] (60/600V)
DC V 60.00/600.0V (Auto-ranging)
±1.0%rdg±3dgt (60V)
±1.2%rdg±3dgt (600V)
Ω 600.0Ω/6.000/60.00/600.0kΩ (Auto-ranging)
±1.0%rdg±5dgt (600Ω)
±2.0%rdg±3dgt (6/60/600kΩ)
Continuity buzzer 600Ω(Buzzer sounds below 90Ω)
Conductor size φ33mm max.
Applicable standards IEC 61010-1 CAT IV 300V / CAT III 600V Pollution degree 2
IEC 61010-031, IEC 61010-2-032, IEC 61010-2-033,
IEC 61326-2-2(EMC), IEC 60529 IP 40, EN50581(RoHS)
Power source R03/LR03 (AAA) (1.5V) × 2
Continuous measuring time Approx.170 hours (When R3 is used)(NCV_LED:off)
(Auto power save : Approx. 10 minutes)
Dimension 204(L) × 81(W) × 36(D)mm
Weight Approx. 220g (including batteries)
Accessories 7066A (Test leads)
9079 (Carrying case)
R03 (AAA) × 2, Instruction Manual