KEW 2413R|LEAKAGE CLAMP METER|PRODUCTS|KYORITSU

Font Size
Small
Medium
Large

LEAKAGE CLAMP METER

KEW 2413R

KEW 2413R
CE
• Large transformer jaws of 68mm diameter makes it possible to clamp on all three or four wires (3 phases) together for leakage current measurement
• Frequency filter switch to eliminate the effect of the harmonics
• 2 way analog output terminal
• Minimum resolution 0.1mA
  • TRUE RMS
  • φ68
  • MAX1000A
  • ACA
  • DATAHOLD
  • PeakHold10/100ms
  • OutPut
  • Filter
  • Backlight
AC A (50/60Hz) 200mA/2/20/200/1000A
±2.5%rdg±5dgt (200mA/2/20A)
±3.0%rdg±5dgt (200A, 0 - 500A)
±5.5%rdg (501 - 1000A)
AC A (WIDE) 200mA/2/20/200/1000A
±1.8%rdg±5dgt (50/60Hz) (200mA/2/20A)
±2.0%rdg±5dgt (50/60Hz) (200A, 0 - 500A)
±5.0%rdg (50/60Hz) (501 - 1000A)
Crest factor 3.0 or less
Conductor size Ø68mm max.
Frequency response 40Hz - 1kHz
Output Waveform :
AC200mV against the maximum value of each range (1000A range is 100mV)
Recorder :
DC200mV against the maximum value of each range (1000A range is 100mV)
Applicable standards IEC 61010-1 CAT III 300V Pollution degree 2
IEC 61010-2-032
Power source 6F22 (9V) × 1 *Continuous measuring time: Approx. 60 hours
Dimension 250(L) × 130(W) × 50(D)mm
Weight Approx. 600g (including battery)
Accessories 9094 (Carrying Case)
6F22 × 1
Instruction Manual
Optional Accessories 7073 (2WAY Output Cord)

Accessories/Optional Accessories /Related Products

  • Instruction Manual
  • Selection Guide

Instruction Manual

Selection Guide

  • Inquiry by e-mail