6020 |
6030 |
6020/30 |
| Insulation Test Specifications |
| Test Voltage |
125V/250V |
250V/500V |
1000V |
Measuring Ranges (MΩ) |
0 ~1.999MΩ 1.00 ~19.99MΩ 10.0 ~199.9MΩ |
0 ~19.99MΩ 10.0 ~199.9MΩ 100 ~1999MΩ |
| (3 auto ranges) |
| Accuracy |
|±2%rdg ±3dgt, ±10%rdg (on 1000~2000MΩ) |
| Open Circuit Voltage |
+20% -0% of Rated Test Voltage |
| Rated Test current |
1mA DC +20%-0% |
| Short Circuit current |
1.3mA DC approx. |
Effect of AC Component of Terminal Voltage |
Within ±10% of reading when 5µF capacitor is connected in parallel on insulation test |
| Overload Protection |
1200V (DC + ACp-p) for 10 seconds |
| Earth Resistance Test Specifications |
| Measuring Ranges(Ω) |
0 ~199.9Ω 100 ~1999Ω (2 auto ranges) |
| Accuracy |
|±2%rdg ±3dgt (at 500Ω auxiliary earth resistance) |
| Measuring Method |
By constant current inverter 820Hz approx. 2mA approx. |
| Overload Protection |
200V AC for 10 seconds between measuring terminals |
| Voltage Test Specifications |
| Measuring Ranges (V) |
0 ~ 199.9/100 ~ 600V (2 auto ranges) |
| Accuracy |
|±1%rdg ±4dgt |
| Sensing |
True RMS |
| Input Impedance |
2MΩ |
| Overload Protection |
900V AC for 1 minute |
| Phase Check Specifications |
| Measuring Range |
100 ~ 600V (50Hz/60Hz) (for checking correct or reverse phase and open phase) |
| General |
| Display |
3 1/2(1999)digit large LCD |
| Response Time |
Approx. 4 seconds for AC voltage and earth resistance tests Approx. 5 seconds for insulation resistance tests. |
| Withstand Voltage |
5550V AC for one minute |
| Effect of Drop |
No electrical and mechanical damage shall occur when the unit is dropped from a height of 1 m onto the concrete floor. |
| Effect of Temperature |
Readings shall not differ greater than specified below when taken at a reference temperature of 23ºC and varied temperature of 0ºC and 40ºC. AC Voltage 3% ±2 dgt insulation resistance and earth resistance 5% ±2 dgt |
| Operating Temperature Range |
0-40ºC |
| Dimensions |
130 × 238 × 207mm (main body plus cord reel module) 105 × 238 × 207mm (main body only) |
| Weight | Approx. 1.6kg (main body only) Approx. 750g (cord reel module only) |
| Power Supply |
1.5V LR6 alkaline battery or equivalent × 8 (for main body only) 1.5V LR6 alkaline battery or equivalent × 1 (probe only) |
| Safety Standard |
IEC 61010-1 CAT.III 600V Pollution Degree 2 |
| Accessories |
7092 (Cord Reel) 8082 (Extension Probe) 7089 (Test Lead (large)) 7090 (Test Lead (small)) 7088 (Test Lead for Phase Check) 7091 (Test Lead) x 1set(red-20m, yellow-10m, green-5m) 8083 (Auxiliary Earth Spikes) x 1set 9081 (Carrying Case) LR6 x 9, Instruction Manual, Shoulder strap, Shoulder Pad, Set of "0" rings |
| Optional |
2417 (Water Proof Leakage Clamp Meter) 7093 (Cord for Extension Probe) 9080 (Aluminum Carrying Case) |