MODEL 2040
Selection Guide Product Catalogue
 
2040
Designed to meet international safety standard IEC 61010-1 CAT.IV 600V.
CAT.IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
Thus, very useful for power distribution companies, power utilities and maintenance fields.
Red LED, as "Non Contact Voltage" function, gives warning to the user on the presence of AC Voltage.
Double molding gives comfortable feeling in palm.
6039 counts with Bar Graph display.
MIN/MAX function enables to keep easily min & max value during measurement.

MODEL 2002PA
 
Selection Guide Product Catalogue
 
2002PA
Can measure large AC current up to 2000A.
Peak hold function.
55mm-dia large tear drop shaped jaws.

MODEL 2002R
 
Selection Guide
 
2002R
Can measure large AC current up to 2000A.
Peak hold function.
55mm-dia large tear drop shaped jaws.

MODEL 2006
  Selection Guide
 
2006
Pocket size, handy clamp meter.
UL listed fire retardant plastic housing case.
Multifunction instrument having voltage and resistance measurement functions in addition to all the ranges incorporated.

MODEL 2007A
 
Selection Guide Product Catalogue
 
2007A
Sleep function to save battery
Data hold function.
Digital display with maximum 4000 counts.

MODEL 2017
  Selection Guide
 
2017
Tear drop shaped jaws for ease of use in tight places and crowded cable areas.
Designed to meet internationally proven safety standards such as
IEC 61010-1, UL3111 and VDE0411.
Three functions in one unit; AC current, AC voltage and resistance.
Resistance range provides audible continuity test.
Frequency response from 40Hz to 1kHz on AC current and voltage ranges.

MODEL 2027
  Selection Guide
 
2027
True RMS reading instrument that permits precise measurements of nonsinusoidal waveform AC current and voltage. Accurate measurements are also possible at low frequencies from 10Hz upwards.
Designed to meet internationally proven safety standards such as
IEC 61010-1, UL3111 and VDE0411.
Three functions in one unit; AC current, AC voltage and resistance.

MODEL 2031
 
Selection Guide Product Catalogue
 
2031
Can measure large AC current up to 200A.
24mm-dia tear drop shaped jaws.


PageTop

Leakage Clamp Meters

MODEL 2412
  Selection Guide
 
2412
Digital clamp meter with tear drop shaped, medium size transformer jaws specially designed for leakage current measurement.
Frequency filter switch to eliminate the effect of harmonics.
Output terminal for connection to recorders and facility to operate from external power supply permit continuous leakage current monitoring.

MODEL 2413F
  Selection Guide
 
2431F
Extra wide transformer jaws are best suited for clamping on all three or four wires (3phases) together for leakage current measurement.
Frequency filter switch to eliminate the effect of harmonics.
Peak hold function.
Output terminal.

KEW 2413R
Leakage Clamp Meter
Selection Guide
 
2413R
Large transformer jaws of 68mm diameter makes it possible to clamp on all three or four wires (3 phases) together for leakage current measurement.
True RMS enables an accurate measurement for distorted waveforms.
Measurement from mA up to AC 1000A
Frequency filter switch to eliminate the effect of the harmonics.
2 way analogue output terminal
Peak hold function
Data hold function
Back light in the LCD (Automatically off)
International safety standard IEC 61010-1 CAT.III 300V

MODEL 2417
 
Selection Guide Product Catalogue
 
2417
Water and dust proof construction. The instrument is protected against water and dust.
True RMS for accurate measurement of non-sinusoidal waveform current.
Selectable frequency response of 50/60Hz only or up to 1kHz.
Automatically turns power off in about 30 minutes to conserve battery life.


MODEL 2431
 
Selection Guide Product Catalogue
 
2431
Frequency Selector Switch to eliminate the effect of harmonics.
Three AC current ranges 20mA/200mA/200A.
20mA range with a minimum resolution of 0.01mA.
Auto power-off function (automatically turns off in about 10 minutes).
Rotary switch for easy one finger power-on and range selection.

MODEL 2432
 
Selection Guide Product Catalogue
 
2432
High Sensitive Model
Frequency Selector Switch to eliminate the effect of harmonics.
Three AC current ranges:4mA/40mA/100A
Data hold function.
Peak hold function.
Sleep function to save battery.
Designed to international safety standard IEC 61010-1 CAT.III 300V

MODEL 2433
 
Selection Guide Product Catalogue
 
2433
Frequency Selector Switch to eliminate the effect of harmonics.
Three AC current ranges:40mA/400mA/400A.
Data hold function.
Peak hold function.
Sleep function to save battery.
Designed to international safety standard IEC 61010-1 CAT.III 300V

MODEL 2433R
 
Selection Guide
 
2434
Frequency Selector Switch to eliminate the effect of harmonics.
Three AC current ranges:40mA/400mA/400A.
Data hold function.
Peak hold function.
Sleep function to save battery.
Designed to international safety standard IEC 61010-1 CAT.III 300V

MODEL 2434
 
Selection Guide Product Catalogue
 
2433R
Least affected by external stray magnetic field.
20mA AC max. in proximity to a 15mm-dia conductor carrying 100A AC
Frequency Selector Switch to eliminate the effect of harmonics.
Data hold function
Sleep function to save battery


PageTop

AC/DC Digital Clamp Meters

MODEL 2046R
Selection Guide Product Catalogue
 
2046R
Designed to meet international safety standard IEC 61010-1 CAT.IV 600V.
CAT.IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
Thus, very useful for power distribution companies, power utilities and maintenance fields.
True RMS enables an accurate measurement (2046R).
Red LED, as "Non Contact Voltage" function, gives warning to the user on the presence of AC Voltage.
Double molding gives comfortable feeling in palm.
6039 counts with Bar Graph display.
MIN/MAX function enables to keep easily min & max value during measurement.

MODEL 2055
Selection Guide Product Catalogue
 
2055
Designed to meet international safety standard IEC 61010-1 CAT.IV 600V.
CAT.IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
Thus, very useful for power distribution companies, power utilities and maintenance fields.
Red LED, as "Non Contact Voltage" function, gives warning to the user on the presence of AC Voltage.
Double molding gives comfortable feeling in palm.
6039 counts with Bar Graph display.
MIN/MAX function enables to keep easily min & max value during measurement.

MODEL 2056R
Selection Guide Product Catalogue
 
2056R
Designed to meet international safety standard IEC 61010-1 CAT.IV 600V.
CAT.IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
Thus, very useful for power distribution companies, power utilities and maintenance fields.
True RMS enables an accurate measurement (2056R).
Red LED, as "Non Contact Voltage" function, gives warning to the user on the presence of AC Voltage.
Double molding gives comfortable feeling in palm.
6039 counts with Bar Graph display.
MIN/MAX function enables to keep easily min & max value during measurement.

KEW 2003A
 
Selection Guide Product Catalogue
 
2003A
Equipped to measure both AC and DC current with transformer jaws of large diameter.
Can measure AC and DC currents up to 2000A.
Output terminal for connection to recorders.
AC/DC voltage, resistance measurement and continuity functions also available.

MODEL 2004
  Selection Guide
 
2004
Smallest clamp meter capable of AC and DC current measurements.
20A range has a minimum resolution of 0.01A AC/DC.
AC/DC voltage and resistance measurement functions also available.

MODEL 2009A
 
Selection Guide Product Catalogue
 
2009A
True RMS reading instrument ideal for accurate measurement of distorted waveforms and non-sinusoidal waveforms arising from thyristors.
Can measure AC and DC currents up to 2000A.
Output terminal for connection to recorders.

MODEL 2010
  Selection Guide
 
2010
High sensitivity, miniature AC/DC clamp meter.
0.1mA minimum resolution for AC current and 1mA minimum resolution for DC current.
Output terminal for recorder connection.

MODEL 2033
 
Selection Guide Product Catalogue
 
2033
Smallest clamp meter capable of AC and DC current measurements.
300A auto ranging has minimum resolution of 0.01A AC/DC.
Auto-zero function to allow one touch zero adjustment.

MODEL 2037
  Selection Guide Product Catalogue
 
2037
Measures both AC and DC current and voltage with high accuracy.
True RMS reading instrument that permits precise measurements of non-sinusoidal waveform AC current and voltage. Accurate measurements are also possible at low frequencies from 10Hz upwards.
Peak, average and frequency measurement functions.

PageTop

Fork Current Tester

MODEL 2300R
 
Selection Guide Product Catalogue
 
2300R
True RMS reading is an essential feature for accurate measurement.
“Non Contact” voltage function indicates the presence of AC voltage by warning the user with an audible signal.
Set the DC current range to zero in one touch with the Zero Adjust function.
Auto Power Off.
Data Hold (AC A / DC A only).
Designed to international safety standard IEC 61010-1 CAT.III 300V.

PageTop

Analogue Clamp Meters

MODEL 2608A
 
Selection Guide Product Catalogue
 
2608A
DC voltage range is also available especially for checking emergency battery operated power supply.
Can measure temperature using optional probe.
Tear drop shaped transformer jaws for ease of use.

MODEL 2805
  Selection Guide
 
2805
Range switch selects only one rotary scale at a time, making it easy to take readings correctly.
A long time seller with proven reputation world wide for its easy-to-use functions.

PageTop