New AC/DC Clamp Sensor |
 |
8115 |
| |
|
| |
| • |
Permits extension of the AC and DC current ranges of almost any Digital Multimeters (DMMs) without breaking the circuit under test. |
| • |
Using KEW 8115 with KEW 1051/1052 (DMM) the display can be set for direct reading in A. |
|

 |
|
 |
| |
|
| |
| Measuring range |
AC 0.1~130Arms (185Apeak) |
DC 0~±180A |
| Output voltage |
AC 10mV/A |
DC 10mV/A |
| Accuracy |
±1.2%rdg±0.4mV (50/60Hz) ±2.5%rdg±0.4mV (40~1kHz) |
±1.2%rdg±0.4mV (*) |
| Low battery warning |
2.2V±0.2V or less - Red LED flash (1.9V±0.2V - Automatically power off) |
| Conductor size |
Max. Φ12mm |
| Withstand voltage |
AC 3540V (RMS 50/60Hz) for 5 sec. |
| Operating temperature & humidity range |
-10 to 55ºC, relative humidity 85% or less (no condensation) |
| Output impedance |
Approx. 10Ω or less |
| Applicable standards |
IEC 61010-1 CAT.III 300V Pollution degree 2, IEC 61010-2-032, IEC 61326-1 |
| Power source |
DC3V (size AAA alkaline battery LR03×2pcs) * Continuous use: approx. 40 hours (Auto power off: approx. 20 minutes) |
| Cord length |
Approx. 1,200mm |
| Output connector |
Φ4mm banana plug |
| Dimensions |
127(L)×42(W)×22(D) mm |
| Weight |
Approx. 140g |
| Accessories |
Soft case, LR03×2, Instruction manual |
|
| * |
This accuracy is defined after the completion of the Kew 8115 zero-adjustment whilst connected to a DMM. |
|

|
|